1,000 kVA diesel generator — models, fuel consumption and price.
A 1,000 kVA standby generator delivers about 800 kW at 0.8 power factor (roughly 909 kVA prime). At 75 % load it burns around 126 litres of diesel per hour. BRO Global supplies brand-new 1,000 kVA sets in Saudi Arabia at 60 Hz — open, silent canopy or containerized — with OEM datasheets, manufacturer warranty and a priced offer within 24 hours.
800 kW
Output at 0.8 PF
909 kVA
Prime rating (≈)
126 L/h
Fuel at 75 % load (≈)
1,000 L
8-hour base tank (≈)
What a 1,000 kVA generator typically powers
- ✓A data centre or critical facility
- ✓An industrial plant or petrochemical site
- ✓A mall, hospital complex or giga-project camp
- ✓A paralleled multi-set power station
Selection chart
Models around 1,000 kVA we supply
Ratings within about 15 % of 1,000 kVA at 60 Hz (Saudi grid) and 50 Hz (GCC). Prime shown as standby ÷ 1.1; final figures in the datasheet with your offer.
| BRO model | Brand | Hz | Standby | Prime | Engine |
|---|---|---|---|---|---|
| PK1000-50 | Perkins | 50 | 1,000 kVA | 909 kVA | 4008-TAG1 |
| BD1000-50 | Baudouin | 50 | 1,000 kVA | 909 kVA | 12M26G900/5 |
| DS950-50 | Doosan | 50 | 950 kVA | 864 kVA | DP222LB |
| BD940-50 | Baudouin | 50 | 940 kVA | 855 kVA | 12M26G825/5 |
| PK900-50 | Perkins | 50 | 900 kVA | 818 kVA | 4006-23TAG3A |
| PK1100-50 | Perkins | 50 | 1,100 kVA | 1,000 kVA | 4008-TAG2 |
| CU1100-50 | Cummins | 50 | 1,100 kVA | 1,000 kVA | KTA38-G5 |
| PK850-50 | Perkins | 50 | 850 kVA | 773 kVA | 2806A-E18TTAG5 |
| PK975-60 | Perkins | 60 | 975 kVA | 886 kVA | 4008-TAG1 |
| BD1050-60 | Baudouin | 60 | 1,050 kVA | 955 kVA | 12M26G900/6 |
| CU940-60 | Cummins | 60 | 940 kVA | 855 kVA | QSK23-G3 |
| PK938-60 | Perkins | 60 | 938 kVA | 853 kVA | 4006-23TAG3A |
| PK1100-60 | Perkins | 60 | 1,100 kVA | 1,000 kVA | 4008-TAG2 |
| PK888-60 | Perkins | 60 | 888 kVA | 807 kVA | 2806A-E18TTAG5 |
| BD880-60 | Baudouin | 60 | 880 kVA | 800 kVA | 12M26G704/6 |
Ratings are typical standby kVA at 0.8 PF (1500 rpm at 50 Hz, 1800 rpm at 60 Hz); prime is shown as standby ÷ 1.1. Exact prime/standby ratings, fuel consumption, dimensions and weight are confirmed in the OEM datasheet issued with your offer. Alternator (Leroy Somer / Stamford) and enclosure are selected on the quote form.
Generator FAQ
1000 kVA — Generator FAQ
How many kW is a 1,000 kVA generator?
How much fuel does a 1,000 kVA generator use?
Should I buy 1,000 kVA standby or prime?
What is the price of a 1,000 kVA generator in Saudi Arabia?
Request a quote
Tell us the load. We'll send a priced offer within 24 hours.
The more you share, the sharper the offer — but a kVA and a city are enough to start.
Need a generator on site this month?
Call or WhatsApp our team — we answer with availability and a price the same day.