Cummins diesel generators — 33 to 2,500 kVA.
Heavy-duty standby and prime power for facilities that cannot go dark.

Why choose Cummins
Cummins pairs its own engines with a global support network and is the default choice for data centres, hospitals and industrial plants where a missed start is not an option. The KTA and QSK series deliver 1,000 to 2,500 kVA per set and parallel cleanly for multi-megawatt plants.
- ✓Standby, prime and continuous ratings across the range
- ✓KTA38 / KTA50 / QSK60 platforms for 1–2.5 MVA sets
- ✓Paralleling and synchronising for multi-set plants
- ✓Strong 60 Hz line-up for the Saudi grid
Best for: Data centres, hospitals, industrial plants and multi-set standby power.
Selection chart
Cummins selection chart
Every Cummins rating we supply, with the engine model behind it. Filter by frequency and power, then request a quote on the row you need.
Swipe horizontally to view all model details.
| BRO model | Standby | Prime | Engine | Cylinders | |
|---|---|---|---|---|---|
| CU100-60 | 100 kVA | 90.9 kVA | 4BTA3.9-G11 | 4 cyl · TA | |
| CU150-60 | 150 kVA | 136 kVA | 6BTA5.9-G6 | 6 cyl · TA | |
| CU200-60 | 200 kVA | 182 kVA | 6BTAA5.9-G12 | 6 cyl · TA | |
| CU250-60 | 250 kVA | 227 kVA | 6CTA8.3-G2 | 6 cyl · TA | |
| CU300-60 | 300 kVA | 273 kVA | 6CTAA8.3-G14 | 6 cyl · TA | |
| CU375-60 | 375 kVA | 341 kVA | QSL9-G7 | 6 cyl · TA | |
| CU500-60 | 500 kVA | 455 kVA | NTA855-G4 | 6 cyl · TA | |
| CU625-60 | 625 kVA | 568 kVA | QSX15-G9 | 6 cyl · TA | |
| CU750-60 | 750 kVA | 682 kVA | KTA19-G8 | 6 cyl · TA | |
| CU940-60 | 940 kVA | 855 kVA | QSK23-G3 | 6 cyl · TA | |
| CU1265-60 | 1,265 kVA | 1,150 kVA | KTA38-G14 | 12 cyl V · TA | |
| CU1560-60 | 1,560 kVA | 1,418 kVA | KTA50-G3 | 16 cyl V · TA | |
| CU1875-60 | 1,875 kVA | 1,705 kVA | KTA50-G8 | 16 cyl V · TA | |
| CU2500-60 | 2,500 kVA | 2,273 kVA | QSK60-G6 | 16 cyl V · TA |
Ratings are typical standby kVA at 0.8 PF (1500 rpm at 50 Hz, 1800 rpm at 60 Hz); prime is shown as standby ÷ 1.1. Exact prime/standby ratings, fuel consumption, dimensions and weight are confirmed in the OEM datasheet issued with your offer. Alternator (Leroy Somer / Stamford) and enclosure are selected on the quote form.
Generator FAQ
Questions Saudi buyers ask before ordering a generator
Should I order 50 Hz or 60 Hz?
What is the difference between standby and prime rating?
Do Saudi temperatures reduce generator output?
Are the generators new and do they come with warranty?
How fast can you deliver?
Can you supply ATS, synchronising panels and fuel tanks?
Do you provide documents for consultant approval?
Request a quote
Request a Cummins generator offer
The more you share, the sharper the offer — but a kVA and a city are enough to start.
Compare with other brands
Need a generator on site this month?
Call or WhatsApp our team — we answer with availability and a price the same day.