Skip to main content
Diesel Generators

Diesel generators for Saudi projects — sized right, priced within 24 hours.

Brand-new generator sets from 10 to 3,300 kVA across a wide choice of international engine brands. Pick a model from the selection chart, or send us your load schedule and we specify the set, enclosure and controls that fit your site.

10–3,300

kVA range, standby

Multi-brand

engine brands under one supplier

60 / 50 Hz

Saudi grid and export builds

24 h

to a priced technical offer

Brand-new sets only

Factory-assembled and load-tested before dispatch.

OEM documentation

Datasheets and submittals ready for consultant approval.

Manufacturer warranty

Honoured in-Kingdom with local service and spare parts.

Delivery to all 13 regions

Coordinated with your site access and crane needs.

Selection chart

Find your model by power, brand and frequency.

Saudi Arabia's grid is 60 Hz, so the chart opens at 60 Hz. Each row is a set we can supply — click Request quote and the model is added to your enquiry.

Frequency
Brand
Power

Swipe horizontally to view all model details.

Diesel generator models with standby and prime ratings
BRO modelBrandStandbyPrimeEngineCylinders
KU12-60Kubota12 kVA10.9 kVAD1105-E2-BG3 cyl · NA
PK12_4-60Perkins12.4 kVA11.3 kVA403A-11G13 cyl · NA
KU16-60Kubota16 kVA14.5 kVAV1505-E2-BG4 cyl · NA
PK17_5-60Perkins17.5 kVA15.9 kVA403A-15G13 cyl · NA
KU20-60Kubota20 kVA18.2 kVAD1703-E2-BG3 cyl · NA
PK20-60Perkins20 kVA18.2 kVA403A-15G23 cyl · NA
KU26_5-60Kubota26.5 kVA24.1 kVAV2203-E2-BG4 cyl · NA
PK26_6-60Perkins26.6 kVA24.2 kVA404A-22G14 cyl · NA
KU30-60Kubota30 kVA27.3 kVAV2003-T-E2-BG4 cyl · Turbo
PK38_2-60Perkins38.2 kVA34.7 kVA1103A-33G3 cyl · NA
KU40-60Kubota40 kVA36.4 kVAV3300-E2-BG4 cyl · NA
KU49-60Kubota49 kVA44.5 kVAV3300-T-E2-BG4 cyl · Turbo
PK58_7-60Perkins58.7 kVA53.4 kVA1103A-33TG13 cyl · Turbo
PK75-60Perkins75 kVA68.2 kVA1103A-33TG23 cyl · Turbo
CU100-60Cummins100 kVA90.9 kVA4BTA3.9-G114 cyl · TA
PK100-60Perkins100 kVA90.9 kVA1104A-44TG24 cyl · Turbo
PK126_5-60Perkins126.5 kVA115 kVA1104C-44TAG24 cyl · TA
CU150-60Cummins150 kVA136 kVA6BTA5.9-G66 cyl · TA
PK169-60Perkins169 kVA154 kVA1106A-70TAG16 cyl · TA
PK183-60Perkins183 kVA166 kVA1106A-70TAG26 cyl · TA
BD190-60Baudouin190 kVA173 kVA6M11G165/66 cyl · TA
CU200-60Cummins200 kVA182 kVA6BTAA5.9-G126 cyl · TA
PK217-60Perkins217 kVA197 kVA1106A-70TAG36 cyl · TA
CU250-60Cummins250 kVA227 kVA6CTA8.3-G26 cyl · TA
PK250-60Perkins250 kVA227 kVA1206A-E70TAG26 cyl · TA
PK273-60Perkins273 kVA248 kVA1506A-E88TAG26 cyl · TA
CU300-60Cummins300 kVA273 kVA6CTAA8.3-G146 cyl · TA
PK320-60Perkins320 kVA291 kVA1506A-E88TAG36 cyl · TA
PK346-60Perkins346 kVA315 kVA1506A-E88TAG46 cyl · TA
CU375-60Cummins375 kVA341 kVAQSL9-G76 cyl · TA
PK389-60Perkins389 kVA354 kVA1506A-E88TAG56 cyl · TA
PK399-60Perkins399 kVA363 kVA1706A-E93TAG26 cyl · TA
PK438-60Perkins438 kVA398 kVA2206A-E13TAG26 cyl · TA
BD460-60Baudouin460 kVA418 kVA6M21G400/66 cyl · TA
CU500-60Cummins500 kVA455 kVANTA855-G46 cyl · TA
PK563-60Perkins563 kVA512 kVA2506A-E15TAG16 cyl · TA
CU625-60Cummins625 kVA568 kVAQSX15-G96 cyl · TA
PK687-60Perkins687 kVA625 kVA2806C-E18TAG26 cyl · TA
CU750-60Cummins750 kVA682 kVAKTA19-G86 cyl · TA
PK750-60Perkins750 kVA682 kVA2806A-E18TAG36 cyl · TA
BD830-60Baudouin830 kVA755 kVA6M33G715/66 cyl · TA
BD880-60Baudouin880 kVA800 kVA12M26G704/612 cyl V · TA
PK888-60Perkins888 kVA807 kVA2806A-E18TTAG56 cyl · TTA
PK938-60Perkins938 kVA853 kVA4006-23TAG3A6 cyl · TA
CU940-60Cummins940 kVA855 kVAQSK23-G36 cyl · TA
PK975-60Perkins975 kVA886 kVA4008-TAG18 cyl · TA
BD1050-60Baudouin1,050 kVA955 kVA12M26G900/612 cyl V · TA
PK1100-60Perkins1,100 kVA1,000 kVA4008-TAG28 cyl · TA
CU1265-60Cummins1,265 kVA1,150 kVAKTA38-G1412 cyl V · TA
PK1385-60Perkins1,385 kVA1,259 kVA4012-46TWG2A12 cyl V · TA
CU1560-60Cummins1,560 kVA1,418 kVAKTA50-G316 cyl V · TA
BD1650-60Baudouin1,650 kVA1,500 kVA12M33G1400/612 cyl V · TA
PK1669-60Perkins1,669 kVA1,517 kVA4012-46TAG2A12 cyl V · TA
CU1875-60Cummins1,875 kVA1,705 kVAKTA50-G816 cyl V · TA
PK1880-60Perkins1,880 kVA1,709 kVA4012-46TAG3A12 cyl V · TA
CU2500-60Cummins2,500 kVA2,273 kVAQSK60-G616 cyl V · TA

Ratings are typical standby kVA at 0.8 PF (1500 rpm at 50 Hz, 1800 rpm at 60 Hz); prime is shown as standby ÷ 1.1. Exact prime/standby ratings, fuel consumption, dimensions and weight are confirmed in the OEM datasheet issued with your offer. Alternator (Leroy Somer / Stamford) and enclosure are selected on the quote form.

Not sure which size you need?Use the sizing calculator

Open, silent or containerized — built for the site, not the catalogue.

The same engine and alternator can ship three ways. We recommend the enclosure from your noise limits, plant-room space and how the set will be moved.

Open type (skid)

Open type (skid)

Engine, alternator and control panel on a heavy-duty base frame with anti-vibration mounts. Lowest cost and easiest to service — for plant rooms with proper ventilation and exhaust.

Best for: Generator rooms in buildings, factories and hospitals.

Silent canopy

Silent canopy

Weather-proof, sound-attenuated enclosure with residential silencer, lockable doors and integrated base tank. Typical 70–75 dB(A) at 7 m; super-silent options below 65 dB(A) on request.

Best for: Urban sites, compounds, schools and anywhere near occupied buildings.

Containerized (20 / 40 ft)

Containerized (20 / 40 ft)

ISO container with acoustic lining, fuel system, cable trays and ventilation — a complete plant that arrives on a lowbed and is running the same day. Ideal for 800 kVA and above, and for paralleled multi-set plants.

Best for: Large construction sites, industrial plants and temporary power stations.

How it works

From load schedule to commissioning — six steps, one point of contact.

  1. 01

    Share your load or your spec

    Send the load schedule, the consultant's spec, or simply the kVA you have in mind. A five-minute WhatsApp call is enough to start.

  2. 02

    Priced technical offer within 24 hours

    You receive a clear offer: model, engine, alternator, controller, enclosure, options, delivery time and price in SAR including VAT.

  3. 03

    Submittals for approval

    OEM datasheets, drawings and compliance documents formatted for the consultant's approval cycle.

  4. 04

    Factory assembly and load test

    Every set is assembled, load-tested and inspected before it leaves — with the test report in your handover file.

  5. 05

    Delivery and positioning

    Transport to any Saudi region, coordinated with your site access, crane and pad readiness.

  6. 06

    Commissioning and after-sales

    Start-up, ATS integration and operator hand-over — then warranty, service and spare parts in-Kingdom.

Real deliveries

Sets we have actually supplied, installed and commissioned.

Photos from our own dispatches and sites — not stock imagery.

Case study · Riyadh · 2026

2 × 880 kVA Baudouin canopy sets for a Riyadh contractor

Two soundproof-enclosure sets rated 880 kVA standby / 800 kVA prime, each with an original Baudouin 12M26G704/6 V12 engine directly coupled to a Leroy-Somer brushless alternator, 60 Hz, 1800 rpm — supplied with the complete diesel fuel storage and distribution system and installed on site.

  • 2 × 880 kVA standby
  • Baudouin 12M26 V12
  • Leroy-Somer alternator
  • 60 Hz · 1800 rpm
  • Soundproof enclosure
  • Fuel system included
Canopy generator sets staged for handover
Containerized generator on lowbed dispatch
Open generator sets in plant room
On-site generator installation

Generators by city

Generator supply across Saudi Arabia and the Gulf

Local pages for the cities and regions we deliver to most — each with the areas served, the sectors we work with and the questions buyers there ask.

Don't guess the size. Calculate it.

Enter your load in kW, the largest motor and the site temperature — the calculator applies power factor, growth and 50 °C derating and shows the nearest sets from the chart.

Open the sizing calculator

Generator FAQ

Questions Saudi buyers ask before ordering a generator

Should I order 50 Hz or 60 Hz?
Saudi Arabia's grid is 60 Hz, so any set that will run alongside utility power or feed standard local equipment must be 60 Hz (1800 rpm). We supply 50 Hz sets for export projects or equipment specified at 50 Hz.
What is the difference between standby and prime rating?
Standby is the maximum output for emergency use during a utility outage, typically for limited hours per year. Prime is the continuous output at variable load, with a 10 % overload allowance. If the set is your main power source, size on the prime rating.
Do Saudi temperatures reduce generator output?
Yes. Sets are rated at 25–40 °C; above that, engines derate roughly 1 % per °C. For 50 °C summers we size with a derating margin and specify tropical radiators, so the set delivers its rated output when you need it most.
Are the generators new and do they come with warranty?
All sets are brand-new, factory-assembled and load-tested, with the OEM engine serial and manufacturer warranty. Warranty is honoured in-Kingdom with service and spare parts through our network.
How fast can you deliver?
Common ratings (up to ~500 kVA Perkins and Cummins) are typically available within 2–6 weeks; larger and containerized sets are built to order with 8–14 weeks lead time. Ask for current availability — stock changes weekly.
Can you supply ATS, synchronising panels and fuel tanks?
Yes. We supply automatic transfer switches, Deep Sea synchronising controllers for multi-set plants, day tanks and bulk fuel systems with piping, and we install and commission the complete package.
Do you provide documents for consultant approval?
Yes — OEM datasheets, GA drawings, alternator and controller data, and compliance certificates are prepared as a technical submittal for the consultant's approval before manufacturing.

Request a quote

Tell us the load. We'll send a priced offer within 24 hours.

The more you share, the sharper the offer — but a kVA and a city are enough to start.

  • ✓Model, engine and alternator
  • ✓Controller, ATS and options
  • ✓Delivery time and price in SAR incl. VAT
  • ✓Datasheet attached

+966 54 727 2567

power@broglobal.net

Sat–Thu · 9:00 AM – 5:00 PM

Generator specification
Your contact details
Or WhatsApp us

Used only to prepare your offer and never sold — see our Privacy Policy.

Need a generator on site this month?

Call or WhatsApp our team — we answer with availability and a price the same day.

Contact the generator team